ADVANCED INTERLINK CORPORATION
ANET-16/4
NIC Type |
ARCnet |
Transfer Rate |
2.5Mbps |
Data Bus |
16-bit ISA |
Topology |
Star |
Wiring Type |
RG-62A/U 93ohm coaxial |
Boot ROM |
Available |
NODE ADDRESS |
||||||||
Node |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
SW1/7 |
SW1/8 |
0 |
- |
- |
- |
- |
- |
- |
- |
- |
1 |
Off |
On |
On |
On |
On |
On |
On |
On |
2 |
On |
Off |
On |
On |
On |
On |
On |
On |
3 |
Off |
Off |
On |
On |
On |
On |
On |
On |
4 |
On |
On |
Off |
On |
On |
On |
On |
On |
251 |
Off |
Off |
On |
Off |
Off |
Off |
Off |
Off |
252 |
On |
On |
Off |
Off |
Off |
Off |
Off |
Off |
253 |
Off |
On |
Off |
Off |
Off |
Off |
Off |
Off |
254 |
On |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
255 |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Off |
Note: Node address 0 is used for messaging between nodes and must not be used. A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 1 is the Least Significant Bit and switch 8 is the Most Significant Bit. The switches have the following decimal values: switch 1=1, 2=2, 3=4, 4=8, 5=16, 6=32, 7=64, 8=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, off=1) |
RESPONSE/RECONFIGURATION TIMEOUTS |
|||
Response Time |
Reconfiguration Time |
J1A |
J1B |
74.7 m |
840ms |
Open |
Open |
283.4 m |
1680ms |
Open |
Closed |
561.8 m |
1680ms |
Closed |
Open |
1118.6 m |
1680ms |
Closed |
Closed |
Note:All NICs on the network must have this option set the same. |
BOOT ROM |
||
Setting |
JP1C |
|
» |
Disabled |
Open |
|
Enabled |
Closed |
BASE MEMORY ADDRESS |
||||||
Address |
JP2A |
JP2B |
JP2C |
JP2D |
JP2E |
|
|
C0000h |
Closed |
Closed |
Closed |
Closed |
Closed |
|
C4000h |
Closed |
Closed |
Open |
Closed |
Closed |
|
CC000h |
Closed |
Open |
Closed |
Closed |
Closed |
» |
D0000h |
Closed |
Open |
Open |
Closed |
Closed |
|
D4000h |
Open |
Closed |
Closed |
Closed |
Closed |
|
D8000h |
Open |
Closed |
Open |
Closed |
Closed |
|
DC000h |
Open |
Open |
Closed |
Closed |
Closed |
|
E0000h |
Open |
Open |
Open |
Closed |
Closed |
I/O BASE ADDRESS |
||||
Address |
JP3A |
JP3B |
JP3C |
|
|
260h |
Closed |
Closed |
Closed |
|
290h |
Closed |
Closed |
Open |
» |
2E0h |
Closed |
Open |
Closed |
|
2F0h |
Closed |
Open |
Open |
|
300h |
Open |
Closed |
Closed |
|
350h |
Open |
Closed |
Open |
|
380h |
Open |
Open |
Closed |
|
3E0h |
Open |
Open |
Open |
INTERRUPT REQUEST |
|||||||||
IRQ |
JP4A |
JP4B |
JP4C |
JP4D |
JP4E |
JP4F |
JP4G |
JP4H |
JP4I |
2 |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
3 |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
Open |
5 |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
Open |
7 |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
Open |
10 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
11 |
Open |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
12 |
Open |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
15 |
Open |
Open |
Open |
Open |
Open |
Closed |
Open |
Open |
Open |
DIAGNOSTIC LED(S) |
||
LED |
Status |
Condition |
LED1 |
On |
Data is being transmitted or received on CON1 |
LED1 |
Off |
Data is not being transmitted or received on CON1 |
LED2 |
On |
Data is being transmitted or received on CON2 |
LED2 |
Off |
Data is not being transmitted or received on CON2 |
LED3 |
On |
Data is being transmitted or received on CON3 |
LED3 |
Off |
Data is not being transmitted or received on CON3 |
LED4 |
On |
Data is being transmitted or received on CON4 |
LED4 |
Off |
Data is not being transmitted or received on CON4 |