C F S - 1 0 6 0 A C A B O CONNER NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 3.5"/SLIMLINE Cylinders 3640| 2064| 516| 1024 Capacity form/unform 1065/ MB Heads 6| 16| 64| 16 Seek time / track 14.0/ ms Sector/track | 63| 63| 63 Controller IDE / ATA2 FAST/ENHA Precompensation Cache/Buffer 64 KB MULTI-SEGMEN Landing Zone Data transfer rate 3.500 MB/S int Bytes/Sector 512 16.600 MB/S ext PIO4 Recording method RLL1/7 ZBR operating | non-operating -------------+-------------- Supply voltage Temperature *C | Power: sleep W Humidity % | standby W Altitude km | idle W Shock g | seek W Rotation RPM 3600 read/write W Acoustic dBA spin-up W ECC Bit MTBF h 300000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** J U M P E R S ********************************************************************** SEAGATE ST31081A/31060A QUICK REFERENCE GUIDE Jumper Setting ============== Front View +---- Not used | +-- Master ON, Slave OFF (C/D) CS | | (TOP) o o o o o o o o1 Option Block --- o o o o o o o2-------------------- (BOTTOM) +---+---+ | C/D | | Reserved ---+ | Cable Select ------+ The C/D jumper is used to determine whether the drive is a master (drive C) or a slave (drive D). The drive is configured as a master, when jumpered, and a slave when not jumpered. Master/Standalone ----------------- CS C/D o o X C/D CLOSED o o x Slave ----- CS C/D o o o All OPEN o o o Cable Select Master or Slave ---------------------------- CS C/D x o o CS CLOSED Cable Select Option enabled X o o When using CS option, the C/D jumper MUST be open All other pins are reserved and should not be used. Master/Slave Configuration -------------------------- When two drives are daisy-chained on the host interface, one must be designated at the master drive (C: drive) and one as the slave drive (D: drive). Commands from the host are written in parallel to both drives. When the C/D jumper on the drive is closed, the drive will assume the role of a master. When C/D is open, the drive will act as a slave. In single-drive configurations, C/D must remain in the closed (master) position. For each command sent from the host, the DRV bit in the drive/head register selects the master or the slave drive. When the DRV bit is reset (0), the master drive is selected, and when the DRV bit is set (1), the slave drive is selected. Once the drives receive the command, only the drive with jumper C/D set to the appropriate position will execute the command. For example, if the DRV bit is set, only the slave drive (jumper C/D open) will execute the command. NOTE If the command is a diagnostic command, both drives will execute the command and the slave will report its status to the master via the Host PDIAG signal. Drive selection always refers to the state of the DRV bit in the Device/Head register and the position of the position of the C/D jumper throughout this manual. Cable Select ------------ This optional method of drive master/slave designation can be enabled by jumper selection as described below. If used, special cabling can be used to selectively ground the CSEL interface signal of the drive intended to be drive C (0). This drive will then function as the master. If CSEL is allowed to float the drive will recognize it- self as drive D (1) and function as the slave. ********************************************************************** I N S T A L L ********************************************************************** -ANY DIREC. Notes on installation ===================== Installation direction ---------------------- horizontally vertically +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | | | | | | | +---------------------+ | +-----+ +-----+ | +-+-----------------+-+ +--+ +--+ | | | | +-----------------+ The drive will operate in all axis (6 directions).