ULTRASTOR CORPORATION
ULTRA 14FB
|
Data bus: |
16-bit, ISA |
Size: |
Three/quarter-length, full-height card |
Hard drive supported: |
Up to seven SCSI drives |
Floppy drives supported: |
Two 360KB, 720KB, 1.2MB, or 1.44MB drives |
CONNECTIONS | |
Function |
Location |
50-pin SCSI connector - internal |
J1 |
50-pin SCSI connector - external |
J2 |
34-pin control cable connector - floppy drive |
J3 |
4-pin connector - Drive active LED |
JP3 |
BIOS ADDRESS* | ||||
Address |
JP11/jumper 1 |
JP11/jumper 2 |
JP11/jumper 3 | |
» |
Disabled |
open |
open |
open |
C400h |
open |
open |
closed | |
C800h |
open |
closed |
open | |
CC00h |
open |
closed |
closed | |
D000h |
closed |
open |
open | |
D400h |
closed |
open |
closed | |
D800h |
closed |
closed |
open | |
DC00h |
closed |
closed |
closed |
I/O PORT ADDRESS* | |||
Address |
JP12/jumper 1 |
JP12/jumper 2 |
JP12/jumper 3 |
330h |
open |
open |
open |
340h |
open |
open |
closed |
310h |
open |
closed |
open |
230h |
open |
closed |
closed |
240h |
closed |
open |
open |
210h |
closed |
open |
closed |
130h |
closed |
closed |
open |
140h |
closed |
closed |
closed |
USER CONFIGURABLE SETTINGS | |||
Function |
Location |
Setting | |
» |
Floppy drive enabled |
JP2 |
closed |
Floppy drive disabled |
JP2 |
open | |
» |
SCSI Termination enabled |
JPTP |
closed |
SCSI Termination disabled |
JPTP |
open | |
» |
I/O and BIOS Address is software configured |
JP12/jumper 4 |
open |
I/O and BIOS Address is jumper configured |
JP12/jumper 4 |
closed |
MISCELLANEOUS TECHNICAL NOTES |
* When JP12/jumper 4 is open (factory default), I/O and BIOS address is software configured. All other jumpers are factory configured - do not alter |